BURNERS CHANGELOG ================== 35353: - Fixed issue that affected out of memory error (reported @ AM Differdange) - Fixed HMI cosmetic issues (English, Spanish and Japanese) - Improved Slag Sample diagnostics message 35183: - Added French translation - Added Japanese translation - Improved heat search periods - Updated company name and logos - Updated user manual - Fixed some chart issues in Overview and Performance charts - Fixed curve statistic labels 29753: - Added HMI Hide on ShadowMode feature: enable in GeneralSettings screen and provide Shadow active status in HeatStatus.RegulatorShadowMode bit in inputs mpa - Fixed Overview Chart minimize problem - Fixed the chemical symbols for elements (sub and sup indexes) - Energy and Mass Balance Screen now shows the complete data series instead of 2 minutes - Fixed the background color of the components visible - Changed title of overview screen for spanish from "Analisis de Escoria" to "Vista General" 26952: - New Screen: Energy And Mass Balance (By default the screen is not enable). - Performance improved (avoiding exception handling by using validation for calculated variables). - New General Setting: Show DRI. - Misc CustomZedGraph improvements: Double Click to edit scales, etc. - New variables added to ModbusMap: Burners.FlowTotCarbInj, Burners.FlowTotO2, Energy.PercScrapMelted and SlagAnalysis.SlagB3Estim. - Screen rendering improved for non-standar display resoutions. 26703: - User preferences for Heat trends variables were not loaded correctly. Proper call to varsManager.AttachVarsManager. - AWV screen were not updating Probability level control, because a wrong path. 26669: - BugFixed: Display Format Magnesite Charge & 0.000 for Carbon 26551: - New SlagAnalysis variables for Dolo, Lime, Magnesite: Bucket, Injected, TopFeed and Total (also Recommended) - Overview and SlagAnalysis screens controls reordered in order to make new variables fit in. 26341: - Bug fixed: When selecting a heat from the timeline it was retrieving always the most recent one by heatnumber 25890: - Added missing translations to Spanish. - Bug fixed: Serie - Adding a new collection of new items with more or equal number of items was not moving the pointer to new position. - Logging Improvement: InnerData info now includes HeatNumber. 25379: - Bug Fixed: Prevent infinite loop checking for calculated variables when there is no Web\ExternalLogs\YYYY\ExternalLogsYYYY.sqlite file. 25117: - AWV variables moved to its own object at the end of the map; Zolo address rolledback to Reserved. - AWV Screen - The level control now shows the Alarm Probability instead of Severity. 25051: - New DRI Profile & Setpoint variable added to Burners object on map. - New Abnormal Vapor color codes - Trend Chart improvements: X Axis zoom, In live charts: show first 15 minutes then auto scroll. - Historical Heat charts response time improved. - Abnormal Vapor Detection: Misc bugs fixed. - New User Defined menu items allows user hook custom charts as menu options. - UI improved for Chart Control: Rows changed for Text (Pencils). 24855: - Tab Analysis in Abnormal Water Leak screen - Progress control to show severity on Abnormal Water Leak screen - Bug Fix: Color coded timeline in Abnormal Water Leak screen - New variables in Abnormal Water Vapor (WaterLeak), Severity, Integrators, etc. - New Alarms object: Move the WaterLeak alarm to this object. Increase Alarms.AbnormalVaporCount with each new alarm. - New BurnerProgram variable added almost to the very end of the final object Burners; added to Overview and Performance screens as well. - IMPORTANT NOTICE: If after upgrading and opening the HMI for more than 2 times it will not update, uninstall program Burners (HMI) and reinstall from http://burnerserver/HMI/. 23878: - Operation Costs: Consumption units from MWh/Ton to KWh/Ton and Kscf/Ton to scf/Ton - Heat trends chart at Performance is now updated also by a change of HeatStatus.HeatSeqNo. - Default ExternalLogsCfg.xml for calculated variables now contains a complete basic setup. - Analysis Profile new Layout Model feature. - Abnormal Vapor Event Editor Dialog - Heat Navigation using time insted of heat number. - Abnormal Vapor Screen - Mark all heats where a leak was present Between LastFirstSightEventTime and LastFixEventTime. - Fix button available when an active leak is present. 23698: Burners Operation: Kwh/ton changed to Operative Kwh/ton Bug fixed: Layout in spanish at BurnersOperation screen LogProcessor updated dlls included. 23604: Furnace On restriction removed for saving samples, ppm, events. 23578: New Variables: Temp Estim, PPM Estim and FreeO2 / ton The chart scroll displays complete charts and auto select first visible. New Carbon Estimation query option: Only First Sample. Bug Fixed: Wrong path creation for Free O2, Temp. Estim. and PPM Estim. Bug Fixed: Free O2 path was OK before last changed. 23389: Bug fixed: 1. Missed code - Higlight heats with samples. 2. Missed code - Sort samples for trends. 23377: - Text Changed from Water Leak to Abnormal Vapors - Help Updated - PostUpdate: Install net v4.0 in the IIS before update ApplicationPool 23160: -Timeline control refactored: it now uses TimelineItems instead of HeatSheets -WaterLeak refactored: heats and events with independent navegation -Bug fixes: *Water Leak navigation misc bug fixed *Delete WL Event implemented *Use of strftime('%s', @Timestamp_Column) for timestamp column comparation *If an exception ocurrs in the screen memento loading then loads its default memento *Code clean up 23135: -Added option to disable the Water Leak module in Configuration/System Manager screen. 23124: -WATER LEAK Layout improved -Code clean up, Documentation updated -Overview screen 1. Bugfixed: PencilItem was using IsRemovable to show or not the value insted of show or not the remove button. 2. ProfileChart - Heat Detail now support units in variables names, curves and axis. 3. Overview screen - images added 4. Modbus data package viewer improved. Now is faster and less flinking Features: 1. ModelUtil.LoadPath now support N levels in the path to load. 2. New ModelUtil.UnloadPath to remove sub-model in a given model tree 3. WaterleakEditor showns the heat start time 4. General bugfixes. 23017: 1. Feature: Units attached to variable name on display 2. Bugfixed: Spell error in type field in ObjectsMap 3. gpm and l/min added to units configuration file, translations added. 4. Curve Fit deprecated, code commented. 23001: -Not null validation added at GetAllAsyncProcStatusCompleted. -Water leak variables added to Zolo object 22994: Layout improved - Chart maximize and shrink optimized HeatStatus.POn and HeatStatus.POff datatype changed to "double" Estimation quality semaphore moved to labels (back and fore colors). Also it is only shown when the sample count of the heat is greater than zero. 22960: Bug fixed: Wrong color property used. ForeColor insted of NumberColor. 22946: Bug fixed: Wrong strategy used, displays on chart were not updated. 22937: -Feature: New PencilItemVer2 shows variable´s value. -Expression & calculated variables added to HMI model to display them on live displays. -Minor layout improvement. -For those variables (path) without translation; only last path element will be shown. -Zolo.Temp path was wrong 22904: -Bug fixed: Allow user make a multi selection when selecting a variable for a chart. -Bug fixed: wrong path for Operation Costs process name. -Misc Bugs fixed: 1. Saving Rph datasource with no file selected. 2. analysis profile screen layout. 3. Confirmation message when deleting an analysis profile. 4. Last Datasource auto select after Data source deletion. 22758: Feature: New UserColorsManager to cache the user prefered chart colors. HeatsTrends chart DataSource now keeps tracking in time 22659: Fixed memory leak in RPH reader Minor bug fixes in ProfileAnalisys screen 22629: Recalculation of operation costs External variables configuration file is no longer overwritten with every upgrade 22591 and 22579: Merged from trunk Major bug fixes in Analysis Profile External logs XML Timestamp column changed to AVG as default General validations in External Logs 22549: New Chart Data Source Viewer: Grid view. 22546: DataSource selection settings. 22544: Fixed Scatter & Histogram Chart in Event Log Viewer Fixed chart When moving between heats, adding time, moving time span (dissapearance) Fixed Chart not updating when mode is scatter and XAxis is changed with another variable.